SKU | MX3G-43C-22M | MX3G-70C-48M | MX3G-50C-32M |
Dimension | 134*102*34 mm | 210*146*36mm | 151*96*36mm |
Cutout size | 120*94mm | 192*138mm | 143*86mm |
Power Consumption | 4 – 6W | 6-7W | 5-7W |
HMI | |||
Display | 60K colors resistive touch screen, supports portrait display | ||
Type | 4.3″TFT | 7.0″ TFT | 5.0″TFT |
Display size | 97*56mm | 154*87mm | 108*65mm |
Resolution (pixels) | 480*272 | 800*480 | 800*480 |
RAM | 64MB | ||
ROM | NOR Flash 8MB | NOR Flash 16MB | |
CPU | 32bit CPU 408MHz | ||
COM ports | Type-C HMI download port (can download PLC program through the USB penetrating function), RS232 port | ||
Software | TPWorks HMI programming software | ||
PLC | |||
I/O | Max 12DI/10DO | Max 24DI/24DO | 16DI/16DO |
I/O level | –Fixed MT outputs: Y0, Y1 at 43C and Y0-Y13 at 70C, DC24V active NPN outputs -Input: Passive NPN, public terminal isolated -Transistor output: Low level NPN, COM connect to negative Relay output: Normally open dry contact |
Fixed MT: Low level NPN, COM negative; Input: passive NPN, common isolated | |
DO type and load | -Transistor MT/Hybrid Output MRT -The first two Y0-Y1 circuits are fixed to MT, with an output load of 0.1A/point; -MT: 0.5A/point, 0.8A/4 point COM; MR: 2A/point, 4A/4 point COM. |
-Transistor MT/Hybrid Output MRT -The first 12 Y0-Y13 circuits are fixed to MT. with an output load of 0.1A/point -MT: 0.5A/point, 0.8A/4 point COM, 1.6A/8 point COM; MR: 2A/point, 4A/4 point COM, 5A/8 point COM. |
Transistor MT output, load 0.2A/point |
High-speed counting | Conventional 2-channel single-phase 60KHz+4-channel 10KHz or 1-channel AB (Z) phase 30KHz+1-channelAB (Z) phase 5KHz | ||
High-speed pulse | MT outputs conventional 4 channels, with Y0-Y1 at 100KHz and Y2-Y3 at 10KHz: The total transmission of high-speed counting and high-speed pulses cannot exceed 300KHz | Conventional 4 channels, Y0-Y1 is 100KHz, Y2-Y3 is 50KHz: The total transmission of high-speed counting and high-speed pulses cannot exceed 300KHz | The conventional 4-way Y0-Y1 is 100KHz, and Y2-Y3 is 10KHz; |
Input Analog Output AI/AO |
2 voltage channels 0-10V+2 current channels 0-20MA+1 NTC10K | Equipped with 2 voltage channels 0-10V+1 current channel 0-20mA | |
1 channel voltage 0-10V+1 channel current 0-20MA output |
2 channels of current 0-20MA output | / | |
5AD/2DA | 3AD | ||
COM port | Equipped with two PLC programming ports (1 TYPE-C, faster download speed; 1 RS232 programming port), 1 RS485 | ||
Software | Compatible with PLC programming software GX Developer8.86Q and GX Works2 |